nat vent 暖通名词怎么翻译?

一、nat vent 暖通名词怎么翻译?

Natural Ventilation 暖通

二、麻烦翻译一段英文,关于暖通空调的,谢谢~(专业名词可以不理)

例子:

超载比需要的是一个系统,具有良好的空气分布

然而杂糅的能量。通常最好的空气

配电系统是不变的体积为维护

房间里扔,扩压器的循环系统。系列

风机动力终端单元已经被使用多年

允许改变一次空气同时保持

不断的房间气流。风机动力终端

单元要求定期维修changeout滤波

和电机结束前changeouts长达25年

生活。小球迷和电机效率不高

中央空气处理机组相比。一个典型的

变风量终端设备将允许

气流下降从设计流量到大约40%。

这也会影响到提炼而成的性能。这

变容量感应终端设备允许

基本气流变化下降到40%的设计

而诱导静压空气(或空气)进房间管机

这样的单位,将有大约总气流

80%的设计流程。这有一个最起码的影响

扩压段。这个变量的体积感应终端

单位需要较高的静压力,在操作上比

风机动力单元,但是整体的能量消耗

与其说是自额外的静压是吗

由一个更有效率的风机、电机等。终端

部队有内衬刚性玻璃纤维板

用加强箔的脸。

三、有没有暖通英文文献啊??

If the entering air condition is

changed to Point D at the same wet-bulb temperature but at a higher

dry-bulb temperature, the total heat transfer (Vector DB) remains

the same, but the sensible and latent components change dramati-

cally. DE represents sensible cooling of air, while EB represents

latent heating as water gives up heat and mass to the air. Thus, for

the same water-cooling load, the ratio of latent to sensible heat

transfer can vary significantly.

The ratio of latent to sensible heat is important in analyzing water

usage of a cooling tower. Mass transfer (evaporation) occurs only in

the latent portion of heat transfer and is proportional to the change

in specific humidity. Because the entering air dry-bulb temperature

or relative humidity affects the latent to sensible heat transfer ratio,

it also affects the rate of evaporation. In Figure 2, the rate of evapo-

ration in Case AB (WB − WA) is less than in Case DB (WB − WD)

because the latent heat transfer (mass transfer) represents a smaller

portion of the total.

The evaporation rate at typical design conditions is approximately

1% of the water flow rate for each 7 K of water temperature range;

however, the average evaporation rate over the operating season is

less than the design rate because the sensible component of total heat

transfer increases as entering air temperature decreases.

In addition to water loss from evaporation, losses also occur

because of liquid carryover into the discharge airstream and blow-

down to maintain acceptable water quality.

如果是进入空调

改为D点在同一湿球温度,但在较高

干球温度,总传热(矢量数据库)仍然

相同,但明智的和潜在的组成部分的剧作家,

卡利。明智署署长代表空气冷却,而电子束代表

潜热,水热,放弃了对空气质量。因此,

同样的水冷却负荷,潜显热比

转移有很大的差别。

对潜在的比例显热分析是很重要的水

使用的冷却塔。传质(蒸发)只发生在

潜在的传热部分,是成比例的改变

在具体的湿度。由于进入空气干球温度

或相对湿度影响潜到显热传递率,

它也影响到蒸发率。在图2中,土壤水分蒸发的速度,

在个案公司(世行 - WA)的比例是比案例数据库(世行 - 西数较少)

因为潜热转移(质)代表一个较小的

部分总额。

在典型的设计条件下蒸发率约为

1%的水每7 K表温度范围内水流量;

但是,在工作赛季平均蒸发量

低于设计速度,因为总热量合理成分

作为进入空气温度降低转移增加。

除了水的蒸发损失,损失也可能发生

由于结转到液体排放气流吹

到保持可接受的水质。